Vim speed inputs, Motec appendices 67 – MoTeC ACL VIM User Manual

Page 71

Advertising
background image

MoTeC

Appendices

67

AV H4

300

500

AV H5

550

500

AV H6

800

500

AV H7

1050

500

AV H8

1300

500

AV S1

150

2000

AV S2

400

2000

AV D1

550

1000

AV D2

800

1000

AV D3

50

1000

AV D4

300

1000

AV D5

650

1000

AV D6

900

1000

AV D7

150

1000

AV D8

400

1000

AV SPD1

1200

500

AV SPD2

1450

500

VIM Speed Inputs

The Speed inputs can be individually set to be used in one of the two modes:
Hall or Magnetic. The VIM Speed input can also be set to measure analogue
voltages. This is especially useful when setting levels for magnetic type
sensors since the measured voltage can be used to determine the voltage
levels to use for the mag levels.

Note The same pin is allocated twice in the VIM, one input is when the pin is
being measured in analogue voltage mode. The other input is when the same
pin is being measured in a digital mode.

In Hall mode, a 4700 ohms pull-up resistor is connected to 5 V and the trigger
level is set with a single Hall Voltage Threshold setting.

In Magnetic mode, the pull-up resistor is disengaged and the trigger levels
can be varied depending on the input frequency.

Update rate is 100 Hz for speed measurement.