Vim speed inputs, Motec appendices 67 – MoTeC ACL VIM User Manual
Page 71

MoTeC
Appendices
67
AV H4
300
500
AV H5
550
500
AV H6
800
500
AV H7
1050
500
AV H8
1300
500
AV S1
150
2000
AV S2
400
2000
AV D1
550
1000
AV D2
800
1000
AV D3
50
1000
AV D4
300
1000
AV D5
650
1000
AV D6
900
1000
AV D7
150
1000
AV D8
400
1000
AV SPD1
1200
500
AV SPD2
1450
500
VIM Speed Inputs
The Speed inputs can be individually set to be used in one of the two modes:
Hall or Magnetic. The VIM Speed input can also be set to measure analogue
voltages. This is especially useful when setting levels for magnetic type
sensors since the measured voltage can be used to determine the voltage
levels to use for the mag levels.
Note The same pin is allocated twice in the VIM, one input is when the pin is
being measured in analogue voltage mode. The other input is when the same
pin is being measured in a digital mode.
In Hall mode, a 4700 ohms pull-up resistor is connected to 5 V and the trigger
level is set with a single Hall Voltage Threshold setting.
In Magnetic mode, the pull-up resistor is disengaged and the trigger levels
can be varied depending on the input frequency.
Update rate is 100 Hz for speed measurement.