ACL Errors

These errors are generated by the ACL communications system.

2

FRAMING

Incorrect number of samples received.

256

BAD CONFIG

Configuration mismatch between ACL
and device. Resend the configuration.

512

NO DATA

VIMCOM packets have not been found.
Either there is a wiring fault or ACL
Connections is setup incorrectly.

2048

WRONG DATA

VIMCOM packet has bad length.

4096

BUS WARNING

More than 96 errors have occurred on
the CAN bus. Check wiring and
termination resistors. The CAN bus may
still be operational.

8192

BUS OFF

More than 255 errors have occurred on
the CAN bus. CAN communications is
suspended when this error occurs.
Check wiring, termination resistors and
the CAN baud rate. Also check that CAN
HI and CAN LO are correct (not
swapped).

VIMCOM Device Errors.

These error codes are sent once by the VIMCOM device on resuming
data transmission and therefore indicate why data was previously not
being transmitted.

4097

STARTUP

Device has restarted (normally due to
power up) Data is not sent until sync is
achieved.

4098

HALT

Data not sent due to deliberate halt. For
example configuration or firmware being
sent.

4099 OVERRUN

Data

not

sent due to transmit buffer

overrun (possibly due to CAN bus too
busy)

4100

SYNC TIMEOUT

Data not sent due to ACL sync message
timeout (sync not received from ACL)

4101

CAN ERROR

Data not sent due to error on CAN bus