Burkert Type 2300 User Manual

Page 14

Advertising
background image

14

Technical data

Maximum pilot pressure for valves
without pneumatic control unit

Actuator size Actuator material

max. permitted pilot
pressure

6)

ø 50 mm

PPS

10 bar

ø 70 mm
ø 90 mm
ø 130 mm

7 bar

Tab. 4: Pilot pressure for valves without pneumatic control unit

6)

Observe the maximum pressure range according to the
type label!

Operating pressure for control function A

7)

Actuator size

Orifice DN
[mm]

Required pilot
pressure [bar]

Max. sealed

medium

pressure [bar]

ø 50 mm

15

5.5

16

20

5.5

10

25

5.5

5

ø 70 mm

15

5.5

16

20

5.5

16

25

5.5

12

32

5.5

6

ø 90 mm

25

5.5

16

32

5.5

16

40

5.5

12

50

5.5

7

ø 130 mm

40

5.5

16

50

5.5

16

65

5.6

16

Tab. 5: Operating pressure for control function A

7)

The description of the control function (CF) can be found in
chapter entitled “6.2.1. Control functions (CF)”
.

english

Type 2300

Advertising