Burkert Type 2300 User Manual

Page 32

Advertising
background image

32

Maintenance, cleaning

Procedure:

Knock out dowel pin with a suitable pin punch.
Pin punch ø 4 mm, for spindle diameter 10 mm
Pin punch ø 5 mm, for spindle diameter 14 mm

Remove control cone.

Attach new control cone to the spindle.

Align bores of the control cone and spindle.

Support control cone on the cylindrical part with the aid of a
prism or something similar.

Put on dowel pin and carefully knock in with a hammer.

Position the dowel pin in the centre of the spindle axis.

Install the actuator (with control unit) on the valve body

Check the graphite seal and if required, replace it.

WARNING!

Danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorised lubricants only.

Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).

NOTE!

Damage to the seat seal or the seat contour!
• When installing the actuator, ensure that the valve is in open

position.

Control function A:
Without unit control: pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
With unit control: open the valve according to the operating
instructions for the control unit.

Screw actuator into the valve body.
Observe tightening torque (see “Tab. 17”).

english

Type 2300

Advertising