Installation

Other device versions

→

Do not remove actuator unless this is a customer-specific
requirement.

→

Procedure see “Devices with welded body”

.

8.3.

Installation

WARNING!

Risk of injury from improper installation!
Assembly with unsuitable tools or non-observance of the tightening
torque is dangerous as the device may be damaged.
• For installation use an open-end wrench, never a pipe wrench.
• Observe the tightening torque (see “Tab. 16: Tightening torques

of valve body / nipples”).

Dirt trap for devices with authorisation in accordance with DIN
EN 161
In accordance with DIN EN 161 “Automatic shut-off valves for gas
burners and gas appliances” a dirt trap must be connected upstream
of the valve and prevent the insertion of a 1 mm plug gauge.

→

If the authorisation also applies to stainless steel bodies, the
same type of dirt trap must be attached in front of the angle-seat
control valve.

8.3.1. Installation of the valve body

Welded bodies

→

Weld valve body in pipeline system.

Other body versions

→

Connect body to pipeline.

8.3.2. Install actuator (welded body)

Graphite seal

Fig. 18: Graphite seal

→

Check the graphite seal and if required, replace it.

WARNING!

Danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen appli-
cations there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorized lubricants only.

→

Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).