Replacing the wearing parts – Burkert Type 2300 User Manual

Page 30

Advertising
background image

30

Maintenance, cleaning

Visual inspection:
Perform regular visual inspections according to the application
conditions:

Check media connections for leaks.

Check release bore on the tube for leaks.

Release bore

Fig. 24: Release bore

10.2.1. Cleaning

Commercially available cleaning agents can be used to clean the
outside.

NOTE!

Avoid causing damage with cleaning agents.
• Before cleaning, check that the cleaning agents are compatible

with the body materials and seals.

10.3. Replacing the wearing parts

10.3.1. Replacing the control cone set

The control cone set consists of

• Control cone
• Graphite seal

• Dowel pin
• Lubricant

Before the control cone set can be replaced, the actuator must be
removed from the valve body.

DANGER!

Risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
• Before removing a device, switch off the pressure and vent the

lines.

WARNING!

Risk of injury if the wrong tools are used!
It is dangerous to use unsuitable tools for installation work as the
device may be damaged.
• To remove the actuator from the valve body, use an open-end

wrench, never a pipe wrench.

english

Type 2300

Advertising