Installation, Safety instructions – Burkert Type 2300 User Manual

Page 22

Advertising
background image

22

Installation

Spindle

1.4401 / 1.4404


Spindle guide

1.4401 / 1.4404 / 316L

Connections

Pilot air port

prepared for direct connection

Medium connection

Threaded port: G ½ – G 2 ½
(NPT, RC on request)
Welded connection: as per EN ISO 1127
(ISO 4200), DIN 11850 R2
Other connections on request

Media

Control medium

neutral gases, air

Flow media

Water, Alcohol, Fuel,
Hydraulic liquids, Saline solutions,
Lyes, Organic solvents

Installation position

as required, preferably with actuator in
upright position

Protection class

IP67 in accordance with IEC 529/EN 60529

8.

INSTALLATION

8.1.

Safety instructions

DANGER!

Danger – high pressure in the equipment!
• Before loosening the lines and valves, turn off the pressure and

vent the lines.

WARNING!

Risk of injury from improper installation!
• Installation may be carried out by authorised technicians only

and with the appropriate tools!

Risk of injury from unintentional activation of the system and
an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
For control function I – Danger if pilot pressure fails!
For control function I control and resetting occur pneumatically.
If the pressure fails, no defined position is reached.
• To ensure a controlled restart, first pressurize the device with

pilot pressure, then switch on the medium.

Risk of injury from moving parts in the device!
• Do not reach into openings.

english

Type 2300

Advertising