Burkert Type 2300 User Manual

Page 38

Advertising
background image

38

Maintenance, cleaning

Tightening torques of spindle
Spindle
diameter

Orifice
body

Material of
spindle guide

Tightening
torque [Nm]

10 mm

PEEK

6

15

1.4401 / 1.4404
/ 316L

15

20 – 25

25

32

50

14 mm

PEEK

15

25

1.4401 / 1.4404
/ 316L

25

32 – 50

60

22 mm

65

1.4401 / 1.4404

60

Tab. 19: Tightening torques of spindle

Installing the control cone

→

Attach new control cone to the spindle.

→

Align bores of the control cone and spindle.

→

Support control cone on the cylindrical part with the aid of a
prism or something similar.

→

Put on dowel pin and carefully knock in with a hammer.

→

Position the dowel pin in the centre of the spindle axis.

Install the actuator (with control unit) on the valve body

→

Check the graphite seal and if required, replace it.

WARNING!

Danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorised lubricants only.

→

Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).

NOTE!

Damage to the seat seal or the seat contour!
• When installing the actuator, ensure that the valve is in open

position.

→

Control function A:
Without unit control: pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
With unit control: open the valve according to the operating
instructions for the control unit.

→

Screw actuator into the valve body.
Observe tightening torque (see “Tab. 20”).