FEC AFC1500 User Manual

Page 100

Advertising
background image

Chapter 5: Control Interfaces

5.11.1 Component Descriptions

Fieldbus Interface Connections

Pin Signal

1

TD+

2

TD-

3

RD+

4

-

5

-

6

RD-

7

-

8

-



Configuration DIP Switch


This switch is not used for FEC IP configuratio
OFF
below) “Fieldbus Configuration” feature.












Status LEDs

LED

1 - Link

2 - Modul

3 - Network Status

4 - Activity

1

2

3

4

AFC1500 Multi-2 Unit Hardware

PAGE 5 - 56

5.11.1 Component Descriptions

Connections

Signal

Note


Normally left unused; to ensure signal integrity, these pins are tied
together and terminated to PE via a filter circuit in the module.


Normally left unused; to ensure signal integrity, these pins are tied
together and terminated to PE via a filter circuit in the module.

DIP Switch

This switch is not used for FEC IP configuration and should be set to all
OFF. The IP address is set-up using the AFC Software (see 5.11.2
below) “Fieldbus Configuration” feature.

LED

State

Description

Off

No Link Established

On

Link Established

Module Status

Off

Not Powered / Not Online

Green solid

Controlled by scanner in run state

Green flashing

Not configured or scanner in idle state

Red solid

A major unrecoverable fault has been
detected.

Red flashing

A minor recoverable fault has been
detected.

Network Status

Off

No power to device or no IP address
has been set.

Green solid

Online. One or more connections
established.

Green flashing

Data size bigger than configured.

Red solid

Duplicate IP address. Fatal error.

Red flashing

One or more connections timed out.

Green / Red

Self test in progress

Activity

Green

Flashes each time a packet is
transmitted or received.

Hardware Manual (Rev2.1)

Normally left unused; to ensure signal integrity, these pins are tied

t in the module.

Normally left unused; to ensure signal integrity, these pins are tied
together and terminated to PE via a filter circuit in the module.

n and should be set to all

up using the AFC Software (see 5.11.2

Description

ed / Not Online

Controlled by scanner in run state
Not configured or scanner in idle state
A major unrecoverable fault has been

A minor recoverable fault has been

No power to device or no IP address

Online. One or more connections

Data size bigger than configured.
Duplicate IP address. Fatal error.
One or more connections timed out.

Flashes each time a packet is
transmitted or received.

Advertising