FEC AFC1500 User Manual

Page 17

Advertising
background image

AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 1 - 3

Chapter 1: Outline

1.2 Functions

The Multi-2 Unit is a complimentary controller device to enhance the AFC1500 SAN Unit capabilities

by providing the communication and the sequence control features required by larger or more

sophisticated multi spindle applications. When a group of AFC1500 Servo Controllers (SAN Units) are

linked to a Multi-2 Unit, the Multi-2 Unit assumes control (over these spindles) of the following

functions:

Input / Output (I/O) connection (including Fieldbus interfaces)

Sequence Control

Parameter Programming

Fastening Data Monitoring & Communication

General Status Indication

Input / Output (I/O) Connection

The Multi-2 Unit assumes control of the control signals (Ex.: STOP, START, REVERSE,

BYPASS, etc.) to all of the AFC1500 Servo (SAN) Controllers connected to it via the RS485

communication port, thus eliminating direct connection & control to the individual spindles

saving costly I/O connection. The control signals for the multi-spindle array can be of

different sources: Signals manually generated by pressing the Control Buttons on the front of

the Multi-2 Unit or I/O (Input/Output) signals from a PLC and / or PC Based Controller.

Additionally, a multitude of (direct connect) Fieldbus interfaces are available when using a

Multi2 Unit.

Sequence Control

The Multi-2 Unit controls the fastening sequencing eliminating the need for external control

devices (PLC) to perform complicated spindle control sequencing. All fastening sequencing is

handled by the Multi-2 Unit. This built in feature allows the Multi-2 Unit to control a variety of

complex sequencing strategies including; incremental fastening steps, spindle grouping,

reject (reverse) strategies, wait timing, multiple starts, etc. Also available are sequence

Input / Output interfaces which allow external control of sequence starting / stopping with

outside automation while in sequence.

Parameter Programming

A Windows® compatible computer running the AFC User Console software package can be

connected to the Multi-2 Unit in order to upload or download the preset data to all the SAN

(Servo) Controllers connected in the multi spindle array. This eliminates the need to program

individual spindles manually.

Fastening Data Monitoring & Communication

The Multi-2 Unit can monitor and process the fastening results collected by the AFC1500 Servo

(SAN) Controllers connected to it. It has four (4) configurable RS232C ports to input and output

fastening data results. Data monitoring / saving is also a function of the AFC User Console

software package.

As an added feature, the Multi-2 Unit stores previous fastening data in RAM (non-volatile) for

uploading at another time. The number of cycles stored is based on the number of spindles

connected (see chart on page 2-2). The data can be uploaded using the AFC User Console

software package.

Additionally, the Multi -2 comes standard with an dedicated ethernet port to connect to a

computer running the AFC User Console Software package making it easier to connect to most

computers without serial convertors. As an option, the Multi - 2E comes with an additional

ethernet port for reporting of resultant fastening data to host systems.

General Status Indication

A set of indicator LED’s provide the status for Power On, Busy, Total Accept, Total Reject and

Abnormal conditions.

Advertising