AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 4 - 16

Chapter 4: Installation & Wiring

Out Port 1

These signals will output when the fastening sequence reaches a step that

has a [PLC OUTPUT] instruction inserted. Used to provide sequence

operation status to external PLC’s and/or control outputs for slide motion,

lights, & buzzers, etc without the use of a PLC. (The AFC User Console

Software can set these outputs on and off in the fastening sequence)

Out Port 2

Out Port 3

Out Port 4

Out Port 5

Out Port 6

Out Port 7

Out Port 8

Spindle in Bypass

Signal is active when any of the connected spindles are bypassed either from

San Unit bypass input signals or from the San Unit bypass switch.

Current Limit Warning

Active when the high current limit has been exceeded. This can be used to

identify potential motor failure before total failure occurs by identifying high

current draws over what the typical current draw is for the application.

Always ON / OFF

Can be used to set outputs ON or OFF. Typically used in conjunction with

Bank Outputs to monitor which Bank is selected.

[Table 2 – Sequence Select Output]

Sequence

Output 3

Sequence

Output2

Sequence

Output1

Sequence

Output0

Selected Fastening

Sequence No.

OFF

OFF

OFF

OFF

1

OFF

OFF

OFF

ON

2

OFF

OFF

ON

OFF

3

OFF

OFF

ON

ON

4

¥

¥

¥

¥

¥

ON

ON

ON

OFF

15

ON

ON

ON

ON

16