4 ouput signals (ch1 ~ ch16) – FEC AFC1500 User Manual

Page 103

Advertising
background image

AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)

PAGE 5 - 59

Chapter 5: Control Interfaces

5.11.4 Ouput Signals (CH1 ~ CH16)

The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the Multi-2
Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers).
See Section 4.7.3 for available output signals.

CH. No.

Bit

Signal

FEC Multi-2

Bank

Bit

Output CH.

No.01

0bit

Total Reject

1

1

1bit

Total Accept

1

2

2bit

Abnormal

1

3

3bit

Ready

1

4

4bit

Busy

1

5

5bit

End

1

6

6bit

Sequence Output 0

1

7

7bit

Sequence Output 1

1

8

8bit

Sequence Output 2

1

9

9bit

Sequence Output 3

1

10

10bit Spindle in Bypass

1

11

11bit

Current Warning

1

12

12bit

Spindle No.1 Accept

1

13

13bit

Spindle No.1 Reject

1

14

14bit

Spindle No.1 ABN.

1

15

15bit

Spindle No.1 BYP

1

16

Output CH.

No.02




0bit

Spindle No.2 Accept

1

17

1bit

Spindle No.2 Reject

1

18

2bit

Spindle No.2 ABN

1

19

3bit

Spindle No.2 BYP

1

20

4bit

Spindle No.3 Accept

1

21

5bit

Spindle No.3 Reject

1

22

6bit

Spindle No.3 ABN

1

23

7bit

Spindle No.3 BYP

1

24

8bit

Spindle No.4 Accept

1

25

9bit

Spindle No.4 Reject

1

26

10bit

Spindle No.4 ABN.

1

27

11bit

Spindle No.4 BYP

1

28

12bit

Spindle No.5 Accept

1

29

13bit

Spindle No.5 Reject

1

30

14bit

Spindle No.5 ABN.

1

31

15bit

Spindle No.5 BYP

1

32

Output CH.

No.03




0bit

Spindle No.6 Accept

2

1

1bit

Spindle No.6 Reject

2

2

2bit

Spindle No.6 ABN

2

3

3bit

Spindle No.6 BYP

2

4

4bit

Spindle No.7 Accept

2

5

5bit

Spindle No.7 Reject

2

6

6bit

Spindle No.7 ABN

2

7

7bit

Spindle No.7 BYP

2

8

8bit

Spindle No.8 Accept

2

9

9bit

Spindle No.8 Reject

2

10

10bit

Spindle No.8 ABN.

2

11

11bit

Spindle No.8 BYP

2

12

12bit

Spindle No.9 Accept

2

13

13bit

Spindle No.9 Reject

2

14

14bit

Spindle No.9 ABN.

2

15

15bit

Spindle No.9 BYP

2

16

CH. No.

Bit

Signal

Output CH.

No.16

0bit

8

1

15bit

8

32

The CH. No. at the Master input side differs according to node address settings.
Please check before operating the unit.

These Output signals are user

configurable using the AFC User

Console Software and may be

programmed on any designated

bit.

The Output signal mapping

shown is only an EXAMPLE.

The signals may be programmed

for

placement

in

ANY

bit

position.