AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)

PAGE 5 - 8

Chapter 5: Control Interfaces


5.3.4 Ouput Signals (PLC-OUT) Connector

The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the
Multi-2 Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers). These
signals are user configurable using the AFC User Console Software and may be programmed on
any designated pin. Up to 8 separate output data “Banks” can be set up, each with 32 different
output signals. The Output “Bank” is then selected using the Data Select inputs (Data Select 0,
Data Select 1, Data Select 2).

FEC Standard* Output Layout

NO

Signal

Type**

Description

1

Total Reject

NO

Output when the fastening result is a REJECT.

2

Total Accept

NO

Output when the fastening result is a ACCEPT.

3

Abnormal

NO

Output when an Abnormal condition occurs.

4

Ready

NO

Output when the system is in the READY condition.

5

Busy

NO

System is in cycle

6

End

NO

Output when a fastening cycle is complete.

7

Sequence Output 0

NO

Output confirmation of SEQUENCE SELECT 0~4 input
selections.

8

Sequence Output 1

NO

9

Sequence Output 2

NO

10

Sequence Output 3

NO

11

Out Port 1

NO

These signals will output when the fastening sequence
reaches a step that has a [PLC OUTPUT] instruction
inserted.

12

Out Port 2

NO

13

Out Port 3

NO

14

Out Port 4

NO

15

Out Port 5

NO

16

Out Port 6

NO

17

Out Port 7

NO

18

Out Port 8

NO

19

Spindle in Bypass

NO

Output when any connected spindle is in Bypass

20

Current Limit Warning

NO

Active when the high current limit has been exceeded.

21

~

29

As Configured

NO

30

Always ON / Always OFF

NO

See “Output Data Banks” on following page

31

Always ON / Always OFF

NO

See “Output Data Banks” on following page

32

Always ON / Always OFF

NO

See “Output Data Banks” on following page

33

Output Signal Power

Common for output signal.

Sink Type

+0V

34

Output Signal Power

Source Type

+24V

*

This “Standard” layout is only provided as a guide. Any signal may be programmed on any pin using the

AFC Software.

The layout above is programmed standard from FEC. It contains only “Multi” or system signals as shown,

however, individual spindle signals are available and may be programmed (Ex. Individual spindle accept or reject

– See 4.7.3 for complete list of signals that may be programmed on these pins)

** Type: NO = (Normally Open)

For Output Signal definition see Section 4.7.3.









Advertising