FEC AFC1500 User Manual

Page 114

Advertising
background image

AFC1500 Multi-2 Unit Hardware Manual (Rev2.1)

PAGE 5 - 70

Chapter 5: Control Interfaces

5.12.1 Component Descriptions

Fieldbus Interface Connections

Pin Signal

Note

1

TD+

2

TD-

3

RD+

4

-

Normally left unused; to ensure signal integrity, these pins are tied
together and terminated to PE via a filter circuit in the module.

5

-

6

RD-

7

-

Normally left unused; to ensure signal integrity, these pins are tied
together and terminated to PE via a filter circuit in the module.

8

-











Status LEDs

LED

State

Description

1 – Link/Activity

Green

Link Established

Green, Flashing

Receiving/Transmitting data

Off

No Link Established or power off

2 - Communication
Status

Off

Offline

Green solid

Online, Run

-

Connection established

-

IO controller in RUN

Green, 1 flash

Online, Stop

-

Connection Established

-

IO controller in STOP

3 - Module Status

Off

No power or not initialized

Green solid

Initialized, no error

Green, 1 flash

Diagnostic data available

Green, 2 flashes Blink. Factory ID tool

Red, 1 flash

Configuration Error

-

Too many modules

-

I/O from IO controller config.
Too large

-

Configuration Mismatch (no
module, wrong module)

Red 3 flashes

No station name or no IP address
assigned

Red, 4 flashes

Internal error

4 – Not Used




1

2

3

4

Advertising