5.8.4 Output Signals

The Multi-2 Unit is capable of providing over 570 Output signals to indicate the status of the Multi-2
Unit and of all the AFC1500 SAN Controllers connected to it (up to 31 controllers).
See Section 4.7.3 for available output signals.

Address

Signal

FEC Multi-2

Bank

Bit

RX(n+0)0

Total Reject

1

1

RX(n+0)1

Total Accept

1

2

RX(n+0)2

Abnormal

1

3

RX(n+0)3

Ready

1

4

RX(n+0)4

Busy

1

5

RX(n+0)5

End

1

6

RX(n+0)6

Sequence Output 0

1

7

RX(n+0)7

Sequence Output 1

1

8

RX(n+0)8

Sequence Output 2

1

9

RX(n+0)9

Sequence Output 3

1

10

RX(n+0)A

Spindle in Bypass

1

11

RX(n+0)B

Current Warning

1

12

RX(n+0)C

Spindle No.1 Accept

1

13

RX(n+0)D

Spindle No.1 Reject

1

14

RX(n+0)E

Spindle No.1 ABN.

1

15

RX(n+0)F

Spindle No.1 BYP

1

16

RX(n+1)0

Spindle No.2 Accept

1

17

RX(n+1)1

Spindle No.2 Reject

1

18

RX(n+1)2

Spindle No.2 ABN

1

19

RX(n+1)3

Spindle No.2 BYP

1

20

RX(n+1)4

Spindle No.3 Accept

1

21

RX(n+1)5

Spindle No.3 Reject

1

22

RX(n+1)6

Spindle No.3 ABN

1

23

RX(n+1)7

Spindle No.3 BYP

1

24

RX(n+1)8

Spindle No.4 Accept

1

25

RX(n+1)9

Spindle No.4 Reject

1

26

RX(n+1)A

Spindle No.4 ABN.

1

27

RX(n+1)B

Spindle No.4 BYP

1

28

RX(n+1)C

Spindle No.5 Accept

1

29

RX(n+1)D

Spindle No.5 Reject

1

30

RX(n+1)E

Spindle No.5 ABN.

1

31

RX(n+1)F

Spindle No.5 BYP

1

32

RX(n+2)0

Spindle No.6 Accept

2

1

RX(n+2)1

Spindle No.6 Reject

2

2

RX(n+2)2

Spindle No.6 ABN

2

3

RX(n+2)3

Spindle No.6 BYP

2

4

RX(n+2)4

Spindle No.7 Accept

2

5

RX(n+2)5

Spindle No.7 Reject

2

6

RX(n+2)6

Spindle No.7 ABN

2

7

RX(n+2)7

Spindle No.7 BYP

2

8

RX(n+2)8

Spindle No.8 Accept

2

9

RX(n+2)9

Spindle No.8 Reject

2

10

RX(n+2)A

Spindle No.8 ABN.

2

11

RX(n+2)B

Spindle No.8 BYP

2

12

RX(n+2)C

Spindle No.9 Accept

2

13

RX(n+2)D

Spindle No.9 Reject

2

14

RX(n+2)E

Spindle No.9 ABN.

2

15

RX(n+2)F

Spindle No.9 BYP

2

16

Address

Signal

Description

For

CC-Link

Comm.

Only

RX(n+x)0

Unusable

The last 16 bits are reserved for CC-Link

Communication only,

regardless of how many

stations are set.

RX(n+x)F

Unusable

These Output signals are user

configurable using the AFC User

Console Software and may be

programmed on any designated

bit.

The Output signal mapping

shown is only an EXAMPLE.

The signals may be programmed

for

placement

in

ANY

bit

position.