FEC AFC1500 User Manual

Page 28

Advertising
background image

AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)

PAGE 4 - 4

Chapter 4: Installation & Wiring

4.3 Input Power Connection

An auto sensing power supply allows for input power in the range of 100 ~ 220VAC single phase,

50/60 hertz. Adequate circuit protection must be provided. Recommended conductor size should be

a minimum of #18AWG.

Wiring Chart

Mating Connector

Manufacture:

Amp

Housing Part No.:

1-178128-4

Contact Part No.:

1-175218-3 (Qty.-3)

** To standardize components, FEC cable part

#FEB-1260 may be used due to the fact that

pin #2 is not connected internally.

4.4 RS485 Connection

The Multi-2 Unit uses an RS485 port to perform the communication operations with the AFC1500

Servo (SAN) Controllers. This port has two channels CH1 and CH2. CH1 is dedicated to handle all

preset data upload and download, fastening results monitoring and collection. Channel CH2 is a high

speed connection to all AFC1500 Servo Controllers. It controls all required commands to perform the

fastening cycle.

RS485 port specifications (RJ45)

Speed

9600, 19200, 38400 baud

Cable

Std Cat 5 Ethernet

Maximum number of

connected devices

31

Protocol

Proprietary

Operating Voltage

RS485 Standard

RS485 Wiring







Pin

Description

4

100 ~ 220VAC +/-15%

3

100 ~ 220VAC +/-15%

2

No Connection **

1

Frame Ground

NO Signal Name

Channel

1 TX+ / RX+

CH1

2 TX- / RX-

CH1

3 RX+

CH2

4 TX-

CH2

5 TX+

CH2

6 RX-

CH2

7 GND

8 GND

1

8

4
3
2
1

Advertising