FEC AFC1200 User Manual

Page 10

Advertising
background image

)(& ,QF

2-3b.

The pulldown menu will display three input mode selections:

[FASTENING]

Fastening parameter set screen

[SPEED]

Speed parameter set screen

[REVERSE]

Reverse parameter set screen

2-3c. Using

the

[↑] [↓]

keys, select the desired input mode and depress the

[↵]

key. The selected input mode screen will now be displayed.

FIG. 7-1-2-3 set parameter [INPUT MODE]

7.1.3 Fastening Parameter Setup

The function of this screen is to preset the following parameters:

Fastening method

Yield (control values)

Tool type

Yield (monitor values)

Torque (control values)

Torque rate (monitor values)

Torque (monitor values)

Angle (control values)

Angle (monitor values)

3-1.

Select Fastening Method

3-1a. Move the cursor on the menu bar to [INPUT MODE], select [FASTENING] and

depress the

[↵]

key. The screen displayed will be the "SET PARAMETER

(FASTENING)" screen. (Check the PARAMETER No. to ensure the correct number
has been selected).

3-1b. Depress the [SEL] key. The fastening method will be highlighted. Use the

[←]

[→]

keys to scroll through the fastening method options and depress the

[↵]

key to

select an option. The screen will change to the "SET PARAMETER (FASTENING)"
screen for the selected fastening method.

NOTE: Clockwise (CW) or counterclockwise (CCW) fastening is chosen as part of the fastening

method.
For Angle Method, three (3) options are available: CCW, CW SNUG and CW SEAT.
Typically, SNUG method should be chosen for a clockwise fastening. (SEAT method is
primarily used in Systems operating outside of the United States.)

FIG. 7-1-3-1 set parameter Fastening method selection

Chapter 7: System Operation

Page 7-10