FEC AFC1200 User Manual

Page 14

Advertising
background image

)(& ,QF

4-2c.

AFter all items have been setup, depress the [SEL] key and the question

"DATA CHANGE OK?" will appear.

4-2d.

SELect YES or NO using the

[←] [→]

keys, then depress the

[↵]

key.

Refer to the "VOCABULARY LIST" sections 7.1.7 through 7.1.12 for details of
presetting for each fastening method and to Chapter 6 for fastening instructions.

NOTES:

1. IF incorrect numerical data is entered, the System will display "INPUT ERROR".

2. "FReerun Time" and "Initial Time" may be set in either seconds or revolutions.

3. OFfset Check is only performed when either an input signal is present, or the

sequence program OFFSET CHeck (OF) function is enabled (set to "O").

4. The actual duration of high speed rundown time is equal to "Freerun" minus "Initial" time.

5. "1st time" minus "Freerun time" equals "Slowdown time"

6. When Speed change or 1st Torque is sensed, the System switches to Torque Speed.

7.1.5 REVERSE PARAMETER SETUP

THE function of this screen is to preset the following parameters:

REVERSE SPEED

[RPM]

REVERSE TORQUE

[TQ]

REVERSE TIME [SEC]

REVERSE ANGLE

[DEG]

REVERSE REVOLUTIONS

[REV]


5-1

SELECT INPUT MODE

5-1a.

MOVe the cursor on the menu bar to [INPUT MODE], select [REVERSE] and

depress the

[↵]

key. THe screen displayed will be the "SET PARAMETER

(REVERSE)" screen. Check the Parameter Number to ensure that the correct
number has been selected. THE screen will change to display the "SET
PARAMETER (REVERSE)" screen.

5-1b.

DEPREss the [SEL] key and the cursor will move to the first position for

numerical entry.

Chapter 7: System Operation

Page 7-14

Advertising