FEC AFC1200 User Manual

Page 33

Advertising
background image

)(& ,QF

7.3.4 Vocabulary List [Fastening Data]

PEAK TORQUE

Highest torque value measured during fastening.


OFFSET TORQUE

Prevailing torque value measured during Offset Check
(Check must be enabled via sequence or external input).

FINAL TORQUE

Final torque value measured upon completion of fastening.


FINAL ANGLE

Final angle value measured upon completion of fastening
(measured from snug torque).

ELONGATION ANGLE

Angle value measured from the detected yield point to
completion of fastening.

ELONGATION LENGTH

Calculated amount of permanent elongation of the fastener.


1ST TORQUE RATE

Highest 1st Torque Rate value when using the Integrated

HIGH

Torque Rate calculation method. Average 1st Torque Rate

value when using the Point-to-Point calculation method.

1ST TORQUE RATE

Lowest 1st Torque Rate value when using the Integrated

LOW

Torque Rate calculation method. Not utilized when using
the Point-to-Point calculation method.


2ND TORQUE RATE

Highest 2nd Torque Rate value when using the Integrated

HIGH

Torque Rate calculation method. Average 2nd Torque Rate
value when using the Point-to-Point calculation method.

2ND TORQUE RATE

Lowest 2nd Torque Rate value when using the Integrated

LOW

Torque Rate calculation method. Not utilized when using
the Point-to-Point calculation method.

3RD TORQUE RATE

Highest 3rd Torque Rate value when using the Integrated

HIGH

Torque Rate calculation method. Average 3rd Torque Rate

value when using the Point-to-Point calculation method.

3RD TORQUE RATE

Lowest 3rd Torque Rate value when using the Integrated

LOW

Torque Rate calculation method. Not utilized when using
the Point-to-Point calculation method.


1ST RATE INC TORQUE

Change in torque as measured from Threshold 1 torque until
1st Torque/Angle


1ST RATE INC ANGLE

Change in angle as measured from Threshold1 torque until
1st Torque/Angle


2ND RATE INC TORQUE

Change in torque as measured from 1st Torque/Angle until
Crossover Rate 2 Torque/Angle


2ND RATE INC ANGLE

Change in angle as measured from 1st Torque/Angle until
Crossover Rate 2 Torque/Angle


3RD RATE INC TORQUE

Change in torque as measured from Crossover Rate 2
Torque/Angle until completion of fastening.

3RD RATE INC ANGLE

Change in angle as measured from Crossover Rate 2
Torque/Angle until completion of fastening.

Chapter 7: System Operation

Page 7-33

Advertising