FEC AFC1200 User Manual
Page 17
)(& ,QF
6-2b. The cursor will move to the next item to be entered until all items have been
entered.
6-2c. After all items have been entered or changed, depress the [SEL] key. The
question "DATA CHANGE OK?" will appear in the lower right hand corner.
6-2d. Select YES or NO using the
[←] [→]
keys and depress the
[↵]
key.
or details of
presetting for each fastening method and to Chapter 6 for fastening instructions.
NOTE:
1. IF incorrect numerical data is entered, the sYstem will display "INPUT ERROR".
7.1.7 vOCABULARY LIST 1 [FASTENING] TORQUE CONTROL
FIG. 7-1-7 set parameter [FASTENING] torque method
FULL SCALE TORQUE
MAXIMUm transducer monitoring capacity
TORQUE METHOD
(CW/CCW)
Torque Control method
ANGLE METHOD
Angle Control method
(CW-SNUG/CW-SEAT/CCW)
* Seat Method - Angle count starts at 1st Torque Rate
(calculated zero point)
* Snug Method - Angle count starts at Threshold 2 Torque
Chapter 7: System Operation
Page 7-17