FIG. 7-9-6b Input Data Format [SYSTEM CONFIGURATION (4)]

NOTE: The input data stream must be a formatted input that will always be received in the

same configuration.

Example: the first five characters in the input data stream are part number. the next
character is a space (20 hex). the next six characters represent the part serial number.
(Refer to the first row (00) of the chart in Figure 7-9-6b and to the related description below.)

1. The first five positions would be configured with "FB". "FB" is the identifying value used in

the header and line format configuration for SYSTEM CONFIGURATION screens (1), (2)
and (3). It identifies the first block of data received via the RS232C input port.

RS232C #1 DATA = FB

RS232C #2 DATA = FC

RS232C #3 DATA = FD

RS232C #4 DATA = FE

2. The next character would be configured as a space (20 hex).

3. The next six positions would be configured with "FC". "FC" is the identifying value used in

the header and line format configuration for SYSTEM CONFIGURATION screens (1), (2)
and (3). It identifies the second block of data received via the RS232C input port.

4. if additional data is input via the input data stream and it will not be used in the header and

line format configuration for SYSTEM CONFIGURATION screens (1), (2) and (3), it
should be configured as an unused RS232 data number. in this example "FD".

If the input data stream is less than 128 characters, the unused positions
should be configured with a null character (00 hex).