FEC AFC1200 User Manual

Page 82

Advertising
background image

)(& ,QF

Number of Groups

Data is saved continuously with no grouping.

Type of Separation

Data separation must be configured in System
Configuration (1) Header and Line Format.

Custom Data

Does not apply to Free Format mode.

Data Select

Items chosen through this menu bar option are disregarded.
Data items are chosen through System Configuration (1)
Header and Line Format.

3-5b.

[FILE FORMAT] must be set to "Free Format". If "Statistics Format" is chosen, then
perform set-up procedure "A" earlier in this Section.

3-6b.

Enter one of the FILE START FUNCTION options. When the Data File is generated
in Free Format, these two (2) functions operate as described below:

3-6b1. "Manual" File Start operation requires activation of data save through the Start
option on the Data File Utility screen menu bar. Data will save to the file continuously
until: "Stop" is entered from the menu bar, the disk/diskette fills to capacity, or the
equipment is powered down.

3-6b2. "Automatic" File Start operation activates data save with the first fastening
when the cycle counter is at zero. If the equipment operates in Manual File Start for
several cycles and is then switched to Automatic File Start, data save will not
continue. After Automatic File Start is initiated, data will save to the file until: "Stop" is
entered from the menu bar, the disk/diskette fills to capacity, or the cycle count is set
back to zero (as in a power down situation). If Stop is input from the menu bar while
Automatic is chosen, the FILE START FUNCTION will default to Manual operation.

3-7b.

After all applicable items have been set, depress the [SEL] key on the keypad to
activate the data change authorization window.

3-8b.

To activate data collection in Manual File Start, select the Start option on the menu
bar of the Data File Utility screen. The Sampling Status display will flash the [DATA
SAMPLING] message in the upper right corner of the screen.

To activate data collection in Automatic File Start, view the Data File Utility screen to
verify that "Automatic" has been selected as the File Start Function and that the Cycle
Number display is showing "000000" in the upper right corner of the screen. When
the machine begins the first fastening cycle, the Sampling Status display will flash the
[DATA SAMPLING] message in the upper right corner of the screen.

3-9b.

Data files will be created based upon the following format: "NNNNCCCC.PRN"

NNNN = The 4-character [FILE NAME] set-up on the Data File Utility screen.
CCCC = A computer-assigned file number from "0001" - "9999". When the file

size reaches 999,999 bytes, the System will finish saving the current cycle
to the file, then it will increment the file number.

PRN

= The file type extension

3-10b. To stop data collection, move the cursor on the menu bar to STOP and depress the

[

] key. The [DATA COMPLETE] message will appear in the SAMPLING STATUS

display.

3-11b. To print out the Data File Utility screen, move the cursor on the menu bar to [PRINT]

and depress the [

] key.

Chapter 7: System Operation

Page 7-82