7.0.2 Initial Operation

Prior to entering the initial configuration data, turn the key switch located on the front of the
Main Unit from "RUN" mode to "PROGRAM" mode. If data entry is attempted without turning
the key switch to "PROGRAM" mode, the error message "RUN MODE" is displayed at the
bottom of the screen.

The following data represents the recommended procedure for setting initial data presets :

1. MACHINE CONFIGURATION (SECTION 7.10) The configuration of the machine must be

set prior to performing any other operations. FAilure to do so will disable machine
operation.

2. SET SEQUENCE (SECTION 7.5) After the preset data for the "MACHINE

CONFIGURATION" screen has been entered, the sequence of operations for the
fastening System may be setup. This setup must be completed prior to configuring the
fastening presets on the "SET PARAMETER" screens.

3. SET PARAMETER (SECTION 7.1) The final setup prior to basic machine operation is the

data entry for the System's fastening parameters. Once these presets have been entered,
the System will be operational.

4. FASTENING DATA (SECTION 7.3) The System will operate if the fastening data screen

is not configured, but the data generated by the fastening process will not be reported on.
After the fastening data screen is configured, ensure that the RUN/PROGRAM key switch
is set to RUN mode.

THE SYSTEM MUST BE SET-UP COMPLETELY, IN THE
FOLLOWING ORDER, FOR CORRECT OPERATION.

1.

7.10

MACHINE CONFIGURATION

2.

7.5

SET SEQUENCE

3.

7.1

SET PARAMETER
Fastening parameter data
Speed and Time parameter data
Reverse Speed and Reverse Time data
Current and Warning Limits

Chapter 7: System Operation