7.0.3 Backup Operation - Preset File Utility

Prior to loading configuration data, turn the key switch located on the front of the Main Unit
from "RUN" mode to "PROGRAM" mode. If data loading is attempted without turning the key
switch to "PROGRAM" mode, the error message "RUN MODE" is displayed at the bottom of
the screen.

REFER TO SECTION 7.14.0. FOR DETAILED "PRESET FILE UTILITY" OPERATION

The following represents the recommended order of loading for data presets :

1. MACHINE CONFIGURATION (SECTION 7.10) (FILE EXTENSION = .CFG) The

configuration of the machine must be loaded prior to performing any other operations.
Failure to do so will disable machine operation.

2. SET SEQUENCE (SECTION 7.5) (FILE EXTENSION = .SEQ) Once the preset data for

the "MACHINE CONFIGURATION" screen has been loaded, the sequence of operations
for the fastening System may be loaded. This file must be loaded prior to loading the
fastening presets.

3. SET PARAMETER (SECTION 7.1) (FILE EXTENSION = .PAR) The final file to load prior

to basic machine operation is the fastening parameters file. Once these presets have been
loaded, the System will be operational.

4. FASTENING DATA (SECTION 7.3) The SYSTEM will operate if the fastening data screen

is not configured, but the data generated by the fastening process will not be reported on.
After the fastening data screen is configured, ensure that the RUN/PROGRAM key switch
is set to RUN mode.

THE SYSTEM FILES MUST BE LOADED IN THE
FOLLOWING ORDER FOR CORRECT OPERATION.

1.

"MACHINE CONFIGURATION" (????????.CFG)

2.

"SET SEQUENCE"

(????????.SEQ)

3.

"SET PARAMETER"

(????????.PAR)

Fastening parameter data
Speed and Time parameter data
Reverse Speed and Reverse Time data

Current and Warning Limits

Chapter 7: System Operation

Page 7-6

Advertising