7.13

DATA FILE UTILIty

THe function of this screen is to setup the System to collect and save data to a specified disk
drive.

7.13.1 TABLE OF CONTENTs

7.13.1 Table of Contents for Data File Utility screens
7.13.2. Screen Explanation
7.13.3. SCreen OPERATION/PRINT OUT FUNCTIon

7.13.2 SCREEN EXPLANATION

2-1.

The DATA FILE Utility screen is used to collect and save data to either a floppy (FDD)
disk drive or a hard (HDD) disk drive. THE screen is used to set-up the file and to
start the data collection.

2-2.

The screen has 11 selectable and two (2) display-only items, as listed below:

DRIVE:

B (FDD)

SELECt drive using

[←]

[→]

keys

C (HDD)


PATH:

[ABCDEFGH] name of directory set by alphanumeric pulldown

menu. (8 characters max)


FILE NAME:

[ABCD]

Name of file set by alphanumeric pulldown menu.
(4 characters max)


SPINDLE NUMBER:
01 02 03......24

ACtivate a spindle to collect data by setting [*] using

[*] [*] [ ].......[ ]

the [

±

] key followed by the

[↵]

key


SPINDLE DATA:

ALL

Type of data to be collected (ACCEPT, REJECT,
ACCEPT AND REJECT, or ALL)


SUB GROUP
SIZE:

[ 01 ]

SET size of subgroup to be collected (01~99)


NUMBER OF
GROUPS:

[ 01 ]

SET number of subgroups to be collected (01~99)


TYPE OF

SEt type of separation method between data

SEPARATION:

TAB

characters (NONE, SEMICOLON, SPACE, COMMA
CUSTOM, or TAB)

CUSTOM DATA:

[ ]

Selected from pulldown menu that is activated when
CUSTOM is chosen as TYPE OF SEPARATION.

FILE FORMAT: FREE FORMAT

Data is collected in accordance with the System
Configuration (1) screen Header and Line Format
setup. Saves data from all fastenings, regardless of
fastening results. Data fields selected for Header
and Line Format will be used as data save items.

STATISTICS FORMAT

Data is collected in accordance with the

setup in this

screen.

Chapter 7: System Operation

Page 7-77