SPECIFICATIONS

Electrical:

Power Supply Type: MicroPak
Charging Method:

Direct

Output Voltage:

30-100 kV Variable

(100 kV Maximum)

Output Current:

125 µA

Turbine Speed

Control:

Atomizer Module

Part Spray Ability: Determine spray ability of

part to be coated using

Test Equipment (76652)

(Paint Conductivity Meter)

Shaping Air #1

Variable (See “Pressure

(SAI) Supply:

Flow Data Charts” in the

“Introduction” section)

Shaping Air #2

Variable (See “Pressure

(SAO) Supply:

Flow Data Charts” in the

“Introduction” section)

Brake Air Supply

(Nominal):

60-100 psig (414-689 kPa)

Maximum Fluid Pressure Supply:

Paint:

200 psi (1379 kPa)

Solvent:

150 psi (1035 kPa)

Fluid Flow Rate:

25-800 cc/min.

(See exclusion below)

30mm Bell Cup Max. Flow Rate: 300 cc/

min. at 80,000 rpm

55mm Bell Cup Max Flow Rate: 500 cc/

min. at 80,000 rpm

Max. Flow Rate: 800 cc/

min at 70,000 rpm

65mm Bell Cup Max. Flow Rate: 500 cc/

min at 80,000 rpm

Max. Flow Rate: 800 cc/

min. at 70,000 rpm

Bell Cup Cleaning Time

(Internal/External): 2.7 sec. (approx.)

Color Change Time: Dependent on system

configuration, fluid pressures,

fluid viscosity,fluid line

lengths, etc.

Speed Readout: Magnetic pick-up, unidirec-

tional fiber optic transmission

Atomizer

Replacement Time: Less than 5 min.
Bell Cup

Replacement Time: Less than 2 min.
Minimum Control Equipment

Requirements: (Versions listed or higher)

MicroPak

LECU5004-11 (V.3.84)

Atomizer Module A11925-00 (V.0.4)

I/O Module

A11435-00 (V.1.4)

(0.01V) (4-20 mA)

* Specifications and ratings based on testing at sea

level standard conditions.
Air Heater Recommendation:

An Air Heater is recommended for the turbine air

supply. See Air Heater and filteration recommenda-

tion later in this manual

Mechanical (Cont.)

:

Mechanical

:

Length:

(See RMA-560 Tool Point, Center of

Gravity, and Envelope Dimension

(Single and Dual Flex) figure in the

“Introduction” section.)

Diameter: (See RMA-560 Tool Point, Center of

Gravity, and Envelope Dimensions

(Single and Dual Flex) figure in the

“Introduction” section.)

Approximate Weight (Dual Flex)

Atomizer Only:

12.77 lbs. (5.8 Kg) max.

Total Payload with Robot Plate (Dual Flex)

& Adapter:

15.57 lbs. (7.1 Kg) max.

Turbine Type:

Air Bearing Impulse Drive

Turbine Air Supply: Variable (See “Pressure

Flow Data Charts” in the

“Introduction” section.)

Maximum/Minimum

Turbine Speed:

Continuous 80K rpm max.

/20K rpm min. See excep-

tion at “Fluid Flow Rate”

Maximum Angular

Velocity for Turbine

(Robot Motion):

250

°

/sec.

Tubing Bundle

Max. Rotation:

450

°

in Either Direction

Bearing Air Supply

at the Applicator:

90 psig (±10 psi)

(Nominal):

(621 kPa ±69 kPa) 2.9

SCFM (82 slpm)