DISASSEMBLY PROCEDURES

Atomizer Removal / Replacement

Using the applicator removal tool (76772-00) in-

sert the pin diameter of the wrench into one of the

four (4) holes of OD of the quick disconnect ring.

Apply a force to the tool in a counter-clockwise

direction as shown in “Applicator Removal from

Robot” figure.

Applicator Removal from Robot

Lay the applicator on its side of a clean and

secure area, preferably an area where regular

maintenance is performed. Using the large open

end of the bell cup / combo wrench (A12061-00)

on the flats of the turbine shaft, carefully hold

the outside of the bell cup with one hand while

applying a clockwise force to the wrench. The

bell cup is a right hand thread and must be turned

counter-clockwise to remove.

Place the bell cup in a safe and secure place.

Carefully inspect the cup for any damage. If there

is any damage to the cup, it must be replaced.

NOTE

NOTE

W A R N I N G

!

W A R N I N G

!

†

For reassembly instructions, use the

reverse of the following disassembly pro-

cedures.

†

To facilitate atomizer removal from

hose manifold, a robot program should be

made that purges all paints and solvents

from the RMA-560. Ideally it would then

position the bell assembly in a bell remov-

al position where the bell cup is pointed

downward at a 30° angle. Any residual

solvents would be contained in the “J bend“

of the robot wrist.

†

All O-rings described in the “Mainte-

nance” section of this manual should be

lubricated with a food grade petroleum

jelly or with A11545 lubricant.

†

Prior to removing applicator from the ro-

bot, the following tasks must be completed.
• Robot put into E-stop mode, locked and

tagged out.
• All fluid passages are cleaned, purged

out, and depressurized.
• Air turned off.

†

Carefully remove the quick disconnect

ring to ensure any residual line pressure has

been relieved to atmosphere.

†

The bell cup should always be the

first component removed if any mainte-

nance is performed. Following the pro-

cedure will minimize the risk of damage

to the cup.

Bell Cup Removal / Replacement

RMA-560 Single/Dual Purge Direct Charge - Maintenance

Ransburg

LN-9278-13

51