Fluid Tube Removal / Replacement

Removal (Turbine Removed)

Using the fluid tip/tube removal tool (A11229-00),

place the pinned end of the tool towards the fluid

tube retaining nut and engage the pins into the

holes. Turn the tool counter-clockwise to remove

(see “Fluid Tube Removal” figure).

Fluid Tube Removal

Replacement
Lubricate all O-rings with A11545-00 O-ring lubri-

cant. Push the fluid tube into the pocket of the

atomizer body. Seat the tube by pushing while

rocking the tube from side to side. Install the fluid

tube retaining nut over the tube. Tighten the re-

taining nut firmly tight using the removal tool in a

clockwise direction. Tighten to 65-75 lbs0149in

(7.34-8.47 Nm).

Rear Plate / Rear Manifold / Cascade

Removal and Replacement

Removal
Remove the cup wash and the fluid coil fitting from

the rear valve manifold. Both are removed by

turning counter-clockwise. The ferrule(s) should

be retained with the coil and the cup wash line.

Remove the five (5) air bolts using a wide bladed

screwdriver.

Pull both the rear valve manifold and the rear plate

away from the applicator. Loosen the fiber optic

and low voltage cascade connector set screws

about four turns. Push the cascade connector out

of the rear plate towards the front of the applicator,

pull the fiber optic cable out. Both the rear plate

and the rear valve manifold may now be removed.

RMA-560 Single/Dual Purge Direct Charge - Maintenance

Ransburg

LN-9278-13

57