NOTE

1. Petrolatum jell required to aid in

installation

2. Screw driver for repair

3. Sharp blade for cutting tubing

4. Nitrile or latex gloves to grip components

5. Adjustable wrench and flat plate for

installation aid

TUBING BUNDLE ASSEMBLY

FITTING INSTALLATION AND

TUBING REPAIR

To Install:

Install receiver over tube first, then lightly lubricate

the beginning of the barb of the fitting. Push fully

into tube.

Lightly lubricate O.D. of tubing.

Push receiver fully over tubing and barb assembly.

To Remove:

Insert screwdriver into slot.

RMA-560 Single/Dual Purge Direct Charge - Maintenance