Ransburg – Ransburg RMA-560 Single_Dual Purge Direct A13364 User Manual

Page 55

Advertising
background image

Bell Cup Removal

Bell Cup Wrenches

To re-install a cup, position the wrench as shown.

Insert a torque wrench into the square in the wrench

to apply approximately 50-70 lbs•in (5.69-7.91

Nm) torque. Hold the cup and tighten the torque

wrench in a counter-clockwise direction.

Bell Cup Installation

Example: A desired true torque is desired

using a 9-inch effective length torque wrench.

Wrench offset is 3-inches.

L = 9-inches

TT = 50lbs•in

E = 3-inches

DR = is dial reading.

DR = 50 (9)

DR=37.5 lbs•in

(9+3)

NOTE

C A U T I O N

!

†

Failure to replace a damaged bell cup will

cause premature turbine failure. Warranty will

not be honored if the bell cup is damaged.

†

There is a 3-inch center-to-center dis-

tance between the bell cup and the 3/8-

inch socket square on the wrench. This

distance must be factored in when read-

ing the proper torque on the wrench.

NOTE

†

To remove the 30mm Bell Cup, the en-

tire shape air shroud, cup wash tube and

shape air manifold must be removed.

A12061-00 BELL CUP

WRENCH USE ON ALL

BELL CUPS

CW WITH WRENCH

RMA-560 Single/Dual Purge Direct Charge - Maintenance

Ransburg

LN-9278-13

52

Advertising