Bulkhead Cut-Out Diagram

Robot Plate

W A R N I N G

!

†

Cable connector shell must be electri-

cally grounded. Electrical noise or other in-

terference may result.

(3.18mm) in thickness. The bracket should be

made as in “Low Voltage Cable On Robot” figure

to hold the connector from turning. To mate the

connectors, align the raised key section of the

cable on the applicator end with the key groove

of the cable that goes to the MicroPak. Push the

male end into the mating connector until an au-

dible click is heard. Tug on cable to ensure that

it is locked in place. To remove this section from

the robot plate, remove the applicator. Locate

the set screw holding the flanged plastic 9 pin

connector. Loosen with a 3/32” hex key wrench.

Pull the cable out from the robot plate end. Install

new cable In reverse direction, align the 9 pin

connector with the alignment mark on the robot

plate face and tighten set screw. Torque 5-10

lbs•in (0.56-1.13 Nm).

Quick-Disconnect Cables