Shaping air kit #2, Shaping air kit #3, Ransburg – Ransburg RMA-560 Single_Dual Purge Direct A13364 User Manual

Page 40

Advertising
background image

SHAPING AIR KIT #2

A12874-08/09 Dual Flex Shaping Air Kits for

Use with 65mm Bell Cup

As the name implies, both shaping air outlets

supply air that is counter to the rotation of the bell

cup. This combination will provide a pattern size

from 3-inch to 10-inch (76mm - 254mm) depend-

ing on bell rotation speed, fluid flow, and air flow.

Both sets of shaping air holes are independently

controlled. The inner set of holes are supplied by

connecting the “blue” tube labeled “SAI” on the

tubing bundle to a regulated air source. The outer

set of shaping air holes are supplied by connecting

the “gray” tube labeled “SAO” on the tubing bundle

to a regulated source. The air supplies work in

combination with each other to provide desired

results. This combination of shaping air can be

used with any 55mm bell cup.

SHAPING AIR KIT #3

A12874-03/04 Shaping Air Kits (Dual Air 30mm

Bell Cups)

This combination provides for two air sources to

gain better pattern control, eliminates a secondary

“ghost” pattern, and the ability to penetrate into

deep cavities. The first air is connected to the

“blue” tubes labeled “SAI” on the tubing bundle.

This air exits through an annulus between the

outside diameter of the ball cup and the inside

diameter of the shaping air manifold. The second

air is connected to the tube labeled “SAI” and is

“gray” in color. This air exits a concentric series

of holes at the front of the atomizer. This shap-

ing air combination can be used with either the

aluminum 30mm bell cup or the Titanium 30mm

bell cup. “Air Flow” information can be found in

the “Introduction” section of this manual.

NOTE

†

A minimum of 70 slpm (2.6 SCFM)

should always be kept flowing in the in-

ner shaping air passage to keep the face

of the applicator clean during manual

cleaning breaks.

NOTE

†

A minimum of 70 slpm (2.6 SCFM)

should always be kept flowing in the in-

ner shaping air passage to keep the face

of the applicator clean during manual

cleaning breaks.

RMA-560 Single/Dual Purge Direct Charge - Operation

Ransburg

LN-9278-13

37

Advertising