BEARING AIR ADJUSTMENT

The nominal bearing air pressure is 90 psi (620.5

kPa), measured at the rear of the atomizer. Mini-

mum pressure is 80 psi (551.6 kPa) and maximum

pressure is 100 psi (689.5 kPa). The turbine

should never be operated with less than 80 psi

(551.6 kPa) bearing air pressure.

Bearing air must be present when turning the

turbine on. Bearing air must remain on when

the turbine air is turned off until the turbine stops

spinning. Never turn off bearing air to cause the

turbine to stop spinning. If connected, brake air

can be used to slow the turbine.

The RMA-560 is equipped with a bearing air

return line to monitor bearing air pressure at the

turbine manifold. When connected to the remote

Serial Atomizer speed controller, operation of the

turbine will automatically be shut down whenever

the bearing air pressure falls below the dip switch

setting of 80 psi (551.6 kPa).

W A R N I N G

!

W A R N I N G

!

†

DO NOT exceed the maximum rated

operating speed and turbine inlet pressure.

Excessive speed may cause air turbine

damage or damage to the bell.

†

Bearing air

MUST be ON and supplied at

a minimum of 80 psig (551.6 kPa) whenever

the turbine is operated. If not, severe bear-

ing damage will occur. It is recommended

that bearing air be left turned on at all times,

except during maintenance or disassembly.

†

Bearing damage (and subsequent tur-

bine failure) caused by running the turbine

without bearing air

WILL NOT be covered

under the Ransburg warranty.

SHAPING AIR KIT #1

A12874-05/06 Shaping Air Kits (Mono Flex Air

- Direct Charge - for Use with All 65mm Bell

Cups Only)

As the name implies, shaping air outlet supply

air that is counter to the rotation of the bell cup.

This combination will provide a pattern size from

10-inch to 24-inch (250mm - 610mm) depending

on air flow, fluid flow, and cup rotation speed.

Connection is made using the “blue” 8mm tube

labeled “SAI” on the tubing bundle. The other 8mm

tube labeled “SAO” is “gray” in color and must be

plugged. However, if additional air is required, this

tube can be connected to a secondary controlled

air source. Precautions must be taken that one

does not have a significantly higher pressure than

the other to avoid any back flow. This shaping

air combination can be used with any 65mm bell

cup. (See “Pressure and Flow Data Charts” in

the “Introduction” section.)

NOTE

†

A minimum of 70 slpm (2.6SCFM)

should always be kept flowing in the inner

shaping air passage to keep the face of

the applicator clean during manual clean-

ing breaks.

RMA-560 Single/Dual Purge Direct Charge - Operation

Ransburg

LN-9278-13

36

Advertising