Splash Plate Insertion (All Bell Cups)

Turn the splash plate removal tool over and use

the large diameter end to press the splash plate

back in place by hand. It may be necessary on

occasions to use an arbor press to install the

splash plate. Press splash plate to a hard stop

(see “Splash Plate Insertion” figure).

Splash Plate Insertion (30mm)

C A U T I O N

!

†

Failure to replace a damaged bell cup

will cause vibration of the applicator and/or

premature turbine failure.

Shroud Removal / Replacement

Removal

Remove five (5) screws from back of applicator.

Remove break-away ring and quick disconnect

ring. Pull shroud off.

Shroud Removal

A13559-00 SPLIT SHROUD ASSEMBLY

Replacement

Push the shroud back into place. A light tap on the

end may be required to seat the shroud in position.

Slide the quick disconnect ring over the shroud.

Reinstall break-away ring by aligning the four

(4) holes with the dowel pins on the recessed

face of the rear manifold. Reinstall the five (5)

stainless steel screws. Tighten evenly to 15-20

lbs•in (1.69-2.26 Nm) torque. If you are using the

optional plastic break-away screws, tighten evenly

to 5 lbs•in (.56 Nm) torque. The break-away rig

must lie flat against the face of the rear manifold.

C A U T I O N

!

†

DO NOT over-tighten the five (5) optional

plastic break-away screws or they may break

under normal operating conditions.