Ransburg, Troubleshooting guide – Ransburg RMA-560 Single_Dual Purge Direct A13364 User Manual

Page 73

Advertising
background image

Damaged fiber optic cable between

robot plate and control panel

Connection at robot or bell plate

is loose

Fiber optic transmitter failure

Bad transceiver module

Excessive vibration

Turbine is not rotating

Fluid valve does not actuate

Clogged fluid tube

Bad transceiver module

Fluid valve open

Fluid valve seat damaged or worn

Insufficient back pressure to fluid

regulator

Fluid regulator does not control

flow (system)

Atomizer mounting nut is loose

O-ring is missing.

O-ring is damaged

TROUBLESHOOTING GUIDE

(Cont.)

General Problem

Possible Cause

Solution

Speed Feedback

Fault

No Fluid Flow

Continuous Fluid

Flow

Uncontrollable

Fluid Flow

Fluid and/or Air

Leakage Between

the Robot and Bell

Manifold Plates

Repair or replace the fiber optic cable.

Reinstall cable and tighten locking set

screw.

Replace fiber optic transmitter.

Replace transceiver module.

a. Check bell cup for damage.

b. Check bell cup for excessive paint

buildup.

c. Ensure bell cup is tightened properly.

d. Check cup and shaft tapers for clean-

liness.

Verify rotation of turbine (the paint valve

air pilot must be interlocked with the tur-

bine speed feed back signal to ensure that

paint does not flow into the air bearing).

a. Verify that air pilot signal is present.

b. Fluid valve air pilot signal is too low.

Increase air pressure to 70 psig (482.6

kPa) minimum.

c. Replace fluid valve.

Remove and inspect fluid tube.

Replace transceiver module.

a. Remove air pilot signal.

b. If still open, replace fluid valve.

Inspect and retighten

Replace fluid tube with the next smaller

inner diameter size.

Disassemble fluid regulator and inspect

for paint and solvent.

Tighten mounting ring.

Install O-ring.

Visually inspect for damage and replace.

RMA-560 Single/Dual Purge Direct Charge - Maintenance

Ransburg

LN-9278-13

70