2-6 Wiring
2-6-1 Wiring for Power • Emergency Stop
*
The two EMG terminals are emergency-stop switch contact terminals of the contact-b input logic. They have
been shorted at the factory so that an emergency stop will not be actuated.
24 VDC is output to pin 1.
Caution: When wiring power at the customer site, please make sure that the following specifications are met.
Applicable conduit
Single Line -
1.0 (AWG18)
Stranded Line - 0.75 mm
3
(AWG18)
Specification possible conduit
range
Single Line -
0.4 (AWG26) to 1.2 (AWG16)
Stranded Line - 0.3 mm
2
(AWG22) to 1.25 mm
2
(AWG16)
Stranded Diameter - Over
0.18
Length of un-sealed connect wire 11 mm
Applicable tool for button
operation
Minus Driver (axis diameter
3, blade point width 2.6)
Caution: This controller does not have a power switch.