IAI America E-Con User Manual
Page 49
Advertising
35
(7) Acceleration
only
MAX
Selects either the assigned acceleration or the maximum acceleration. Inputs are
either 1 or 0. The initial value is set as 0.
0: Assigned acceleration
The value input in (4) becomes the actual acceleration/deceleration.
1: Maximum acceleration
The maximum acceleration is applied only during acceleration.
The deceleration corresponds to the value input in (4).
Caution:
As a rough guide, enable the acceleration only MAX setting when the actual payload is no more than
one-third of the rated loading capacity.
Check the rated loading capacity of your actuator by referring to the supplied specification list of
supported actuators.