IAI America E-Con User Manual

Page 66

Advertising
background image


52

Position Data Table (Columns with the thick lines indicate the input insert)

No.

Position

Speed

Acc/Dec

Push

Positioning Band

Acc. only Max

0 *

*

*

*

*

*

1 280 200 0.3

50

15

0

2 40 100 0.3

0

0.1

0

:



















T1: Over 6 msec

Time from Command Position Select Input to Start Signal ON


(However, please consider the scan time of the upper controller.)

Please input Command Positron after previous positioning complete turns ON.

Caution:

Positioning complete Output will turn OFF and moving output will turn on once the start signal turns
ON. Please execute Start Signal OFF only after confirming that moving output turns ON with Start
Signal ON status.

In push-motion operation, if the actuator misses the work part, positioning complete

output will not turn on as shown the diagram below. Complete position output and the output during
transfer will turn OFF.














Transfer

Transfer

Advertising