T1: Over 6 msec
Time from Command Position Select Input to Start Signal ON
(However, please consider the scan time of the upper controller)
Caution:
Positioning complete Output will turn OFF and moving output will turn on once the start signal turns
ON. Please execute Start Signal OFF only after confirming that the output during motion turns ON
with Start Signal ON status.
You can cancel the remaining transfer by turning ON the reset input signal while the actuator is held.
(The remaining transfer will be cancelled upon detection of the leading edge of the reset signal.)
Transfer
Over 4 msec