Position Data Table (Columns with the thick lines indicate the input insert)

No.

Position

Speed

Acc/Dec

Push

Positioning Band

Acc. only Max

0 *

*

*

*

*

*

1 150 200 0.1

0

0.1

1

:






















T1: Over 6 msec

Time from Command position select input to start input ON.


(However, please consider the scan time of the upper controller)

Caution:

Positioning complete Output will turn OFF and moving output will turn on once the start signal turns
ON. Please execute Start Signal OFF only after confirming that moving output turns ON with Start
Signal ON status.
As the diagram below shows, if you leave the Start Input as ON, the Positioning Complete Output will
not turn ON even after the actuator transfer completes. The moving output signal does not turn OFF,
either.








If an overload alarm occurs frequently when this function is used, disable the “acceleration only
MAX” function.

Start

Transfer

Positioning Complete

Actuator Transfer

Advertising