IAI America PDR-101-MW User Manual

Page 56

Advertising
background image

46

(5) Ball Screw Lead Length

Name Symbol Unit

Input range

Default value

(reference)

Ball screw lead length

LEAD

mm

0.1~102.4

[A]


Set the ball screw lead length of the actuator in units of millimeter (mm).

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.

(6) Motor

Type

Name Symbol Unit

Input range

Default value

(reference)

Motor type

MTYP

(HEX input)

00~20h

[A]


Set the type of motor according to the type of actuator.

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.


The type and capacity of the motor vary depending on the type of actuator.

The table below lists setting values for motor type according to the type of actuator and motor capacity.

Actuator Actuator

Type Motor

capacity

Setting

value

Type Motor

capacity

Setting

value

RCS-RB7530 60

W

10h

RCS-SM(R)

SS

150 W

15h

RCS-RB7530
RCS-RB7535

100 W

11h

RCS-RB7535 150

W

12h

ISP(D)

IS(D)

IF

FS

100 W

16h

ISP(D)

IS(D)

IF

FS

200 W

17h

RCS-SS(R)

RCS-RA55

ISP(D)

IS(D)

IF

FS
SS

12RS-60

60 W

ISP(D)

IS(D)

IF

FS

400 W

18h

12RS-30 30

W

13h

ISP(D)-W 600

W

19h

ISP(D)-W 750

W

1Ah

RCS-R10I/20I/30I

RCS-G20I

60 W

1Bh

DS-SA4/5 [T1]

20 W

1Fh

RCS-SM(R)

RCS-RA55

RCS-F55

SS

100 W

14h

DS-SA6 [T1]

30 W

20h