(9) Axis

Operation

Type

Name Symbol Unit

Input range

Default value

(reference)

Axis operation type

ATYP

-

0~1

[A]


Set the operation type, i.e., whether the actuator uses a linear axis or rotational axis.

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.

Actuator axis operation type

Setting value (pulse/rev)

Linear axis

0

Rotational axis

1

(10) In-Position Width

Name Symbol Unit

Input range

Default value

(reference)

In-position width

INP

pulse

1~4096

100


Set the number of pulses of the deviation counter at which the positioning completion (INP) signal output is
triggered.

INP turns on when the number of standing pulses of the deviation counter is equal to or less than the
setting value.


„

Calculation formula for the number of pulses for positioning width (mm)

The setting value of the positioning width is converted from mm to pulses using the following formulae:

In the case of linear axis:

(mm/rev)

length

lead

screw

Ball

)

(pulse/rev

pulses

encoder

of

Number

x

(mm)

width

g

Positionin

(pulse)

value

Setting

=


In the case of rotational axis:

rate

reduction

gear

axis

Rotational

x

(deg/rev)

360

)

(pulse/rev

pulses

encoder

of

Number

x

(deg)

width

g

Positionin

(pulse)

value

Setting

=




z

The setting value of this item indicates pulses of the encoder, and is independent of the electronic

gear setting. The number of pulses of the encoder varies depending on the type of actuator. See (8),
“Number of Encoder Pulses.”

Caution