(14) Acceleration Command Value at Homing

Name Symbol Unit Input

range

Default value

(reference)

Acceleration command

value at homing

OACC pulse/sec

2

1000~19267584 [A]


Set the acceleration at homing.

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.


„

Calculation formula of the setting value (pulse/sec

2

) of acceleration (mm/sec

2

)

The setting value of the acceleration is converted from mm/sec

2

to pulse/sec

2

using the following formulae:


In the case of linear axis:


(mm/rev)

length

lead

screw

Ball

)

(pulse/rev

pulses

encoder

of

Number

x

)

mm/sec

(

on

Accelerati

)

(pulse/sec

value

Setting

2

2

=


In the case of rotational axis:


rate

reduction

gear

axis

Rotational

x

(deg/rev)

360

)

(pulse/rev

pulses

encoder

of

Number

x

)

mm/deg

(

on

Accelerati

)

pulse/sec

(

value

Setting

2

2

=





z

The setting value of this item indicates pulses of the encoder, and is independent of the electronic

gear setting. The number of pulses of the encoder varies depending on the type of actuator. See (8),
“Number of Encoder Pulses.”

(15) Offset Amount at Homing

Name Symbol Unit Input

range

Default value

(reference)

Offset amount at homing

OFST

pulse

1~134217727

[A]


Set the amount of movement from the position at which phase Z is detected after reversing at the
mechanical end in a push operation, for the homing operation.

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.

Caution