IAI America PDR-101-MW User Manual

Page 84

Advertising
background image

74


c. Cold Start Level

Alarm code

(HEX)

Name Cause

D03

Count error

Error status of a serial encoder

D08

Encoder communication
CRC error

CRC error (reception error) of a serial encoder

D09

Over speed

The motor revolution speed exceeded the maximum revolution
speed (MAXV) set in the parameter.

D0A

Overload

The effective output torque value exceeded the allowable value
of the motor.

D10

Overcurrent

The output current of the converter part became abnormally
large.

D12

Encoder out

The encoder is not connected.

D13

FPGA error

Error in the FPGA operation clock

D19

Reception timeout error

Error in the FPGA communication processing of a serial encoder
(After the transmission is completed and 4

µs has elapsed, the

reception start bit is still not asserted.)

D0F

IPM temperature error

Abnormal heating of the converter part

E29

EEPROM error

A writing signal is sent to EEPROM when access to EEPROM is
prohibited.

E3E

Parameter sum check
error

Error of sum check value within EEPROM/parameter area

E67

Motor overvoltage

Voltage of the converter part increased abnormally (400 V or
more) due to regenerative voltage, etc.

EA3

AC power supply
interruption detection
error

An AC power supply interrupt was detected.

FFA

Driver part program
processing error

Error in processing of the driver part of a system program

FFB

Feedback pulse data
writing error

Feedback pulse data could not be written within the cycle.

FFD

Control power supply
voltage error

Error in the voltage of the control power supply

FFE

Current sensor error

The offset adjustment amount of the current sensor exceeded
the internally specified value.

FFF

CPU error

The CPU operated abnormally.