IAI America PDR-101-MW User Manual

Page 65

Advertising
background image

55

(21) Jog Deceleration Default Value

Name Symbol Unit Input

range

Default value

(reference)

Jog deceleration default

value

DEC pulse/sec

2

1000~19267584 [A]


Set the default deceleration value used when performing jog operation with the PC software.

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.


„

Calculation formula of the setting value (pulse/sec

2

) of deceleration (G)

The setting value of the deceleration is converted from G to pulse/sec

2

using the following formulae:


In the case of linear axis:


(mm/rev)

length

lead

screw

Ball

)

(pulse/rev

pulses

encoder

of

Number

x

9800

x

(G)

on

Decelerati

)

pulse/sec

(

value

Setting

2

=


In the case of rotational axis:


rate

reduction

gear

axis

Rotational

x

(deg/rev)

360

)

(pulse/rev

pulses

encoder

of

Number

x

9800

x

(G)

on

Decelerati

)

pulse/sec

(

value

Setting

2

=






z

The setting value of this item indicates pulses of the encoder, and is independent of the electronic

gear setting. The number of pulses of the encoder varies depending on the type of actuator. See (8),
“Number of Encoder Pulses.”


Caution