(22) Jog Speed Default Value

Name Symbol Unit Input

range

Default value

(reference)

Jog speed default value

VEL

pulse/sec

1~1092266

[A]


Set the default speed value used when performing jog operation with the PC software.

An appropriate value corresponding to the applicable actuator has been set at shipment from the factory.


„

Calculation formula of the setting value (pulse/sec) of speed (mm/sec)

The setting value of the speed is converted from mm/sec to pulse/sec using the following formulae:

In the case of linear axis:


(mm/rev)

length

lead

screw

Ball

)

(pulse/rev

pulses

encoder

of

Number

x

(mm/sec)

Speed

)

(pulse/sec

value

Setting

=


In the case of rotational axis:


rate

reduction

gear

axis

Rotational

x

(deg/rev)

360

)

(pulse/rev

pulses

encoder

of

Number

x

(deg/sec)

Speed

)

(pulse/sec

value

Setting

=






z

The setting value of this item indicates pulses of the encoder, and is independent of the electronic

gear setting. The number of pulses of the encoder varies depending on the type of actuator. See (8),
“Number of Encoder Pulses.”

Caution