Relevant query command, See also, Pps: setting pps pulse properties – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 437: Function, Command format

423
Set Command Library
$PASHS,POS,3722.2912135,N,12159.7998217,W,15.25*1F
Relevant Query
Command
$PASHQ,CPD,POS
See also
$PASHS,CPD,MOD,BAS
$PASHS,ANH
$PASHS,ANR
PPS: Setting PPS Pulse Properties
Function
This command is used to set the period, offset and GPS
synchronized edge (rising or falling) of the PPS pulse.
Command Format
Syntax
$PASHS,PPS,f1,f2,c3[*cc]
Parameters
Example
Setting the PPS signal to a period of 2 seconds, with an offset
of 500 ms and a GPS-synchronized rising edge:
$PASHS,PPS,2,+500,R*74
Relevant Query
Command
$PASHQ,PPS
See Also
$PASHS,NME (PTT)
Parameter
Description
Range
Default
f1
PPS time period, a multiple or
fraction of 1 second.
• 0: 1 PPS disabled
0 to 1, with 0.1-sec
increments1 to 60,
with 1-sec incre-
ments
0
f2
Time offset in milliseconds.
± 999.9999
0
c3
GPS-synchronized edge code:
• “R” for rising edge
• “F” for falling edge
R, F
R
*cc
Optional checksum
*00-*FF