Query Command Library
Example
$PASHQ,ANP,RCV
$PASHR,ANP,RCV,ASH802147,-2.00,0.70,103.00,-3.4,-2.2,103.80*09
ANR: Antenna Reduction Mode
Function
This command is used to read the current setting for the
antenna reduction mode. This setting defines the physical
location on the system for which the position is computed.
Command Format
Syntax
$PASHQ,ANR[*cc]
Response Format
Syntax
$PASHR,ANR,s1*cc
Parameters
Example
$PASHQ,ANR
$PASHR,ANR,ON*04
Relevant Set
Command
$PASHS,ANR
See also
$PASHS,ANH
Parameter
Description
Range
s1
Antenna reduction mode:
• OFF: The computed position is assumed to be the
location of the antenna’s L1 phase center.
• ON: The computed position is assumed to be the
location of the ground mark.
• ARP: The computed position is assumed to be the
location of the Antenna Reference Plane (ARP).
OFF, ON,
ARP
*cc
Checksum
*00-*FF