Relevant query command, See also, Snm: signal-to-noise ratio mask – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 483: Function, Command format

469
Set Command Library
Parameters
Example
Defining site name “ECC1”:
$PASHS,SIT,ECC1*63
Relevant Query
Command
$PASHQ,SIT
See also
$PASHS,REC
SNM: Signal-To-Noise Ratio Mask
Function
This command is used to mask the signal observations that
do not meet the minimum C/A code signal-to-noise ratio you
specify. This means that only the observations meeting this
requirement will be used in the PVT computation (all the
others will be rejected).
Command Format
Syntax
$PASHS,SNM,d1[*cc]
Parameters
Example
Setting the SNR mask to 45 dB.Hz:
$PASHS,SNM,45*08
Relevant Query
Command
$PASHQ,SNM
Parameter
Description
Range
s
Site name (or site ID), a 4-character string
where “*”, “.”, “/” and “\” are not allowed.
*cc
Optional checksum
*00-*FF
Parameter
Description
Range Default
d1
SNR mask, in dB.Hz
0-60
0
*cc
Optional checksum
*00-*FF