Function, Command format, Relevant query command – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 495: See also

481
Set Command Library
$PASHS,ETH
TLT,CMD: Defining the Trigger String Used to Query the Tiltmeter
Function
This command is used to define the character string that will
query the tiltmeter. The command also specifies the ID of the
receiver port used to communicate with the tiltmeter.
The trigger string is in the form “*xxxxxx” and the default one
is *0100XY.
Command Format
Syntax
$PASHS,TLT,CMD,c1,s2[*cc]
Parameters
Example
Setting trigger string to “*0100XY”, tiltmeter connected to
port F:
$PASHS,TLT,CMD,F,0100XY*19
Relevant Query
Command
$PASHQ,TLT
See Also
$PASHS,TLT,INIT
$PASHS,TLT,INTVL
$PASHS,OUT,x,TLT
Parameter
Description
Range
c1
Receiver serial port connected to the tiltmeter. A, B, F
s2
Trigger string (not including the leading “*”
character)
20 characters max.
*cc
Optional checksum
*00-*FF